In order to get a good purification effect, the maintenance of the clean operating room unit is very important!
Release time:2019-12-12 source:
The normal operation of the clean operating room is the result of the cooperation of all units in the operating room. Therefore, during the operation of the daily operating room, it is very important to maintain the clean operating room unit regularly to ensure the daily purification effect of the operating room. Through the analysis of practical work, the following points need to be mastered for the maintenance of the clean operating room.
First, for the air conditioning unit with self extracting fresh air, the clean operating room shall clean the aluminum filter screen at the air intake at least once a week, and in case of floating flocs and dust weather, it shall clean twice a week. It should be noted that the fresh air unit must be closed before drawing out the aluminum mesh, and the cleaned filter must be dried before installation.
Second, regularly fasten and clean the element gas parts in the electric control cabinet of the air conditioning unit. Fasten the screws of the element gas parts in the electric control cabinet every three months, monitor the working air flow and temperature at full load, and clean the surface of the element gas parts.
Third, the clean operating room needs to regularly check whether the condensate water pipe of the fan is blocked and whether there is water in the air seal. When there is no condensate water in winter, pay attention to check whether the water in the air seal is dry. If it is dry, add water in time to keep it in the water seal state.
Fourth, when the high-efficiency filter alarm device of the control panel gives an alarm, the high-efficiency filter in the purification ceiling shall be checked in time. After 3-4 years of use, the filter screen will be blocked and the pressure in front of the filter screen will rise. At this time, the frequency converter can be adjusted to improve the air pressure and prolong the service life of the high-efficiency filter. If necessary, the high-efficiency filter can also be replaced.
Fifthly, the clean operating room should clean and disinfect the air processor cabinet regularly. In the northern area, considering the high dust content in the air, it is necessary to timely check and replace the primary and intermediate efficiency filters of the self-contained fresh air unit. At the same time, the interior of the cabinet should be checked frequently. If there is dust in the cabinet, it should be cleaned in time. If necessary, fumigation and disinfection can be carried out in the cabinet
Shandong ed purification Engineering Co., Ltd., founded in August 2010, has been committed to the construction of special departments in the hospital for ten years. It is a professional enterprise engaged in purification of clean operating department, decoration of clean operating room, construction of ICU ward, construction of neonatal NICU, CCU ward, hospital laboratory, decoration of central supply room, construction of laminar flow ward and design and construction of vein configuration center. The main service object is a large, medium and small hospital, which has the qualification of professional contracting related to purification engineering. There are many industry cases. Welcome new and old customers to come for consultation. For more knowledge of medical purification industry, please pay attention to WeChat public address: Aide-188 (Ed purify oxygen supply).