Installation skill of fresh air system in clean operating room
Release time:2019-10-22 source:
Do you know what we need to pay attention to when installing the fresh air system in the operating room? In fact, we have seen the fresh air system in the operating room, but few people pay attention to the installation position of the fresh air system in the operating room. For the fresh air system, the installation position is very important. The following small edition will introduce the knowledge about the installation position of the fresh air system in the operating room.
Clean the fresh air system of operating room
Clean the fresh air system of operating room - what is the fresh air system
The fresh air system is a set of independent air treatment system composed of fresh air ventilator and pipeline accessories. The fresh air ventilator filters and purifies the outdoor fresh gas, and delivers it to the indoor through pipeline. The fresh air system is to supply fresh air to the room with special equipment on one side of the enclosed room, and then discharge it from the other side to the outside. A "fresh air flow field" will be formed in the room, so as to meet the needs of indoor fresh air exchange. The implementation scheme is: using high-pressure head, large flow and small power DC high-speed brush less motor to drive centrifugal fan, relying on mechanical strength to supply air from one side to the indoor, and from the other side to force new air flow field in the system by using specially designed fresh exhaust fan to discharge to the outdoor.
It's very important to install the air outlet of the fresh air system
Before the decoration of the fresh air ventilator, the air conditioning designer should communicate effectively with the owner and the decoration designer to design the air outlet and the fresh air system of the air conditioner, so as to work out the most effective and beautiful scheme. Besides choosing the right brand to ensure the product quality, we should also choose the reliable service organization to carry out professional installation for you. If the air outlet position of the fresh air system is not well chosen, it will affect the fresh air intake and the removal of the dirty air to a large extent. The distance between the fresh air inlet and the air suction outlet shall be kept at least 1.5m to prevent the exhaust gas from channeling. The air suction outlet shall be arranged in the bathroom, toilet, storage room, smoking area and other places with serious air pollution. At the same time, it shall be kept at a sufficient distance from the air outlet of the air conditioner to avoid the cold air being sucked away, thus wasting energy.
Air outlet installation precautions for fresh air system of clean operating room
When installing the air outlet of the fresh air system, select the place close to the main engine and open the hole that can be connected with the outdoor. The specification of the hole through the wall is 130 mm. Install the wall to bridge, and use foam agent to seal. The wall bridge should be level with the outside wall. PEF tape shall be used for intermediate transition at the joint of rainproof air vent and wall bridge, and the installation of air vent shall be correct, flat, tight and beautiful.
This is how to install the fresh air system in the operation room. The installation position of the fresh air system not only affects the use effect of the fresh air system, but also affects the service life of the fresh air system. Therefore, when installing the concealed fresh air system, it is necessary to pay attention to its proper installation position.
As a technical enterprise focusing on the design, R & D, construction and installation of purification operating room engineering in Shandong Province, EDE purification has always been firmly on the road of construction and development of purification operating room engineering, and is a truly reliable professional operating room purification implementer for domestic enterprises! For more knowledge of medical purification industry, please pay attention to wechat public number: aide-188 (ED purified oxygen supply)