Composition and advantages of air conditioning unit in laminar flow operating room
Release time:2019-12-13 source:
Composition of air supply unit of purification air conditioner in laminar flow operating room:
Primary efficiency section: primary filtration of large particles of dust in the fresh air to meet the internal health requirements of the unit and reduce the burden of the secondary efficiency section;
Medium efficiency section: filter the secondary dust produced by air through pipes and units to reduce the burden of sub high efficiency filter or high efficiency filter;
Fan section: low noise centrifugal fan is adopted, with low noise and large wind pressure; frequency conversion control can be selected according to customer requirements;
Surface cooling section: the wind speed on the surface of surface cooling plate is less than or equal to 2.5m/s, and it is made of hydrophilic membrane flat fin, which has good heat exchange effect and is not easy to accumulate dust and bacteria, and will not bring water;
Heating section: hot water heating, steam heating, electric heating, etc. can be used; electric heating is made of stainless steel smooth tube, with smooth surface without fins, corrosion resistance, not easy to deposit ash, easy to clean;
Humidification section: dry steam humidification or electrode humidification can be used to ensure that there is no water in the humidifier after shutdown and eliminate the possibility of bacteria breeding in the humidifier;
Advantages of clean air conditioning unit in laminar flow operating room
1. Low investment and high efficiency. It can save 60% equipment investment to install evaporative environmental protection air conditioner in the same area than to install central air conditioner.
2. Low power consumption, low operation cost, only 1 degree per hour. The power consumption of evaporative energy saving and environmental protection air conditioner installed in the same area is about 1 / 8 of that of central air conditioner
3. The air supply is far and the air volume is large. The air supply volume per hour is more than 18000m.
4. Good purified air quality: ventilation, air exchange, purification and odor removal can discharge the indoor air with odor, dust, turbidity and sultry heat, and bring the fresh outdoor air into the clean room. The air filtration is good, and the filtration efficiency of dust with diameter greater than 1 μ m is more than 80%.
5. Obvious cooling effect: generally, the temperature of the unit can reach 4 ℃ - 10 ℃, and the cooling is rapid.
6. Intelligent control of purification: it can turn on, turn off and clean automatically according to the need, so as to realize intelligent control.
Shandong ed purification Engineering Co., Ltd., founded in August 2010, has been committed to the construction of special departments in the hospital for ten years. It is a professional enterprise engaged in purification of clean operating department, decoration of laminar flow operating room, construction of ICU ward, construction of neonatal NICU, CCU ward, hospital laboratory, decoration of central supply room, construction of laminar flow ward and design and construction of vein configuration center. The main service object is a large, medium and small hospital, which has the qualification of professional contracting related to purification engineering. There are many industry cases. Welcome new and old customers to come for consultation. For more knowledge of medical purification industry, please pay attention to WeChat public number: Aide-188 (Ed purification oxygen supply) laminar flow operation room air conditioning unit composition:
Primary efficiency section: primary filtration of large particles of dust in the fresh air to meet the internal health requirements of the unit and reduce the burden of the secondary efficiency section;
Medium efficiency section: filter the secondary dust produced by air through pipes and units to reduce the burden of sub high efficiency filter or high efficiency filter;
Fan section: low noise centrifugal fan is adopted, with low noise and large wind pressure; frequency conversion control can be selected according to customer requirements;
Surface cooling section: the wind speed on the surface of surface cooling plate is less than or equal to 2.5m/s, and it is made of hydrophilic membrane flat fin, which has good heat exchange effect and is not easy to accumulate dust and bacteria, and will not bring water;
Heating section: hot water heating, steam heating, electric heating, etc. can be used; electric heating is made of stainless steel smooth tube, with smooth surface without fins, corrosion resistance, not easy to deposit ash, easy to clean;
Humidification section: dry steam humidification or electrode humidification can be used to ensure that there is no water in the humidifier after shutdown and eliminate the possibility of bacteria breeding in the humidifier;
Advantages of clean air conditioning unit in laminar flow operating room
1. Low investment and high efficiency. It can save 60% equipment investment to install evaporative environmental protection air conditioner in the same area than to install central air conditioner.
2. Low power consumption, low operation cost, only 1 degree per hour. The power consumption of evaporative energy saving and environmental protection air conditioner installed in the same area is about 1 / 8 of that of central air conditioner
3. The air supply is far and the air volume is large. The air supply volume per hour is more than 18000m.
4. Good purified air quality: ventilation, air exchange, purification and odor removal can discharge the indoor air with odor, dust, turbidity and sultry heat, and bring the fresh outdoor air into the clean room. The air filtration is good, and the filtration efficiency of dust with diameter greater than 1 μ m is more than 80%.
5. Obvious cooling effect: generally, the temperature of the unit can reach 4 ℃ - 10 ℃, and the cooling is rapid.
6. Intelligent control of purification: it can turn on, turn off and clean automatically according to the need, so as to realize intelligent control.
Shandong ed purification Engineering Co., Ltd., founded in August 2010, has been committed to the construction of special departments in the hospital for ten years. It is a professional enterprise engaged in purification of clean operating department, decoration of laminar flow operating room, construction of ICU ward, construction of neonatal NICU, CCU ward, hospital laboratory, decoration of central supply room, construction of laminar flow ward and design and construction of vein configuration center. The main service object is a large, medium and small hospital, which has the qualification of professional contracting related to purification engineering. There are many industry cases. Welcome new and old customers to come for consultation. For more knowledge of medical purification industry, please pay attention to WeChat public address: Aide-188 (Ed purify oxygen supply).