What are the main aspects of the medical purification project? We can find that the medical conditions of going to the hospital are much better than before. Whether it is the medical facilities or the medical and health conditions, it is mainly because with the continuous development of the domestic medical system reform and the improvement of people's living standards, the medical conditions of the hospital are constantly improved, and the surgical technology of various medical departments is increasingly difficult and complex, which is beneficial to the cleanness The clean conditions and functional requirements of the operating room are getting higher and higher. The relevant departments of the state have also issued new design standards for the operating Department of the hospital. The purpose is to ensure the infection rate of patients after the operation with reasonable layout and facilities, shorten the recovery time of patients and reduce medical costs.
Introduction to medical purification project
The hospital purification project is a part of the purification project, which generally refers to the central air conditioning plus high-efficiency filter, through the central air conditioning to reach a constant temperature range, and then through the filter to achieve the requirements of dust and bacteria removal. Purification engineering mainly includes: purification workshop, dust-free room, dust-free workshop, clean room, purification room, aseptic room, hospital operating room, purification and decoration engineering; engaged in production of air shower room, transfer window, automatic hand washing dryer, FFU of fan filter unit, super clean workbench, stainless steel table and chair in clean shed, shelf, etc. cleaning technology usually includes: air purification technology, air conditioning technology, water purity Chemical technology, gas purification technology. Let's briefly introduce the purification project of central air conditioning:
In the design scheme of the purification air conditioning system of the operating department and the delivery room of the hospital, considering the local climate characteristics throughout the year, considering the heat transfer through the external enclosure structure of the operating department and the delivery room, which needs cooling in summer and heating in winter, it is necessary to divide the purification air conditioning system of the operating department and the delivery room of the hospital according to the characteristics of the cooling and heating loads of different functional rooms. And according to the local average maximum relative humidity in summer is only 20.8%, there is no possibility of cooling and dehumidification in the air conditioning system in summer, so the purification air conditioning system of the operation Department and the production room can adopt the air purification system of primary return air.
The operating room and clean auxiliary room adopt a fresh air unit to supply fresh air centrally to maintain the positive pressure of the operating room on duty; the non purification area is designed as a comfortable air conditioning system. The air supply of clean operating room adopts laminar high-efficiency air supply ceiling, the air supply in purification area adopts high-efficiency air supply outlet, and the air supply in non purification area adopts diffusers. The air distribution of operating room and delivery room is up supply and down return air, and the air distribution of other areas is up supply and up return air.
Modern hospitals are to do according to strict purification requirements, if not up to standard, it is easy to cause the spread of bacteria. If you need relevant technical scheme of medical purification engineering, you can view the purification engineering cooperation project of Xianji network, hoping to help you.
Shandong ed purification Engineering Co., Ltd. has standardized workshops, workshops, logistics and storage facilities, advanced production equipment and testing instruments in line with the requirements of the drug administration, and advanced production technology. The company has strong human resources and strong R & D, manufacturing and management. Medical devices are related to the health of patients and medical staff. The company always puts quality first. The company has very standardized control and management in the whole process of raw material purchase, production, sales and after-sales service. Business scope: hospital clean laminar flow operating room, disease control center project: related fields: design, installation, manufacturing, commissioning, testing, etc. of hospital (clean laminar flow operating room, sterile ward, ICU, CCU ward), blood station, bioengineering, disease control center, reorganization and other industries constant temperature and humidity purification workshop. For more knowledge of medical purification industry, please pay attention to wechat public number: aide-188 (ED purification oxygen supply)