Cleanroom transfer window | stainless steel clean room transfer window factory wholesale price | Ed purification products
Release time:2015-12-15 source:
Clean room transfer window as a supplementary device clean room, mainly used to transfer clean area and clean area, a non-clean area and clean area between the small items to reduce the number of clean room door, thus reducing the maximum pollution clean areas. Cleanroom Technology transfer window is widely used in micro-biological laboratories, pharmaceutical plants, hospitals, food processing industry, LCD, electronics factory and so on all need to clean up the air spaces.
One: clean room transfer window Features
⒈ short distance transfer window work tops, stainless steel, flat and smooth wear
⒉ transfer window work tops over long distances without power roller, easy and convenient to pass items
⒊ side door with mechanical interlocking or electronic interlocking, electronic latching device to ensure that both sides of the door can not be opened simultaneously in the state.
⒋ clean room transfer window according to customer needs, custom non-standard size and floor-transfer window.
⒌ nozzle outlet winds of up to 20s and above.
⒍ using HEPA filter, filtration efficiency: 99.99%, to ensure the purification level.
⒎ using EVA sealing material, sealed high performance.
⒏ can be paired call walkie-talkie.
Clean room transfer window Price
Two: clean room transfer window Categories
Clean room transfer window is divided into three categories:
1, the electronic chain clean room transfer window
2, mechanical chain transfer window clean room
3, self-purification clean room transfer window.
Clean room transfer window can be divided according to the principle Lin Feng-transfer window and ordinary transfer window, you can make various types of transfer window according to the actual requirements of the system.
Optional accessories: intercom, germicidal lamps and other accessories related functions.
Three: clean room transfer window works
⒈ cleanroom mechanical interlock transfer window: Internal mechanical interlocking forms, when a door opens, another door will not open another door must be closed before another can be opened
⒉ clean room transfer window electronic interlocking devices: the internal use of integrated circuits, electromagnetic locks, control panels and LEDs for interlocking, when one door opens, another fan door light is off, the door can not be told that open, while electromagnetic lock interlocking action. When the door closes, another electromagnetic lock to work, the indicator will light up, indicating that another door can be opened.
Four: the use of clean room transfer window
1 material out of the clean area must be strictly separated from the flow channel, and out of the workshop material-specific channels.
After 2 material enters, raw materials preparation classes from the person in charge of personnel step off the package or the appearance of the cleaning process, the transfer between the shop window to the staging of raw materials; the bag material is removed between the outer packaging after staging by Transfer window into the bag room. Members and comprehensive preparation workshop, packaging material processes responsible for handling the transfer.
3 passing through the transfer window, we must strictly implement the transfer window and outside the door "opening and closing" requirement, two-door can not be opened. Away after goalkeeper materials placed first closed, then open out inside the goalkeeper materials, closed, and so on.
4 clean area when the material sent out, the material should be first delivered to the relevant material intermediate station, opposite the program out of the clean area by material accessed.
5 All semi-finished products shipped from clean areas, need room to the outside of the transfer window from scratch, the logistics channel transported to the packaging room.
6 extremely polluting materials and waste, should be from the private transfer window shipped to non-clean areas.
After 7 material out, clean up the site should be clean rooms or in the middle of each station and the transfer window of hygiene, both inside and outside the transfer window closed door, do the cleaning and disinfection work.
Clean room transfer window specification
V: Cleanroom transfer window constitute Accessories
⒈ stainless steel clean room transfer window
⒉ UV germicidal lamp
⒊ buzzer
⒋ interphone
⒌ electronic interlocking
Six: clean room transfer window practices
⒈ with 0.5% peracetic acid or 5% povidone-iodine solution to clean the items to be delivered.
⒉ transfer window opens the side door and quickly place items to be delivered, with a 0.5% peracetic acid disinfectant spray transfer window closed transfer window side door.
⒊ open clean room transfer window within the UV lamp, UV irradiation items to be delivered at least 15 minutes.
⒋ notification barrier experiments or staff within the system, open the transfer window inside of the door, remove the items.
⒌ clean room transfer window closed inner door.
Seven: the standard clean room transfer window parameter
Title; electronic interlocking transfer window clean room; mechanical interlocking transfer window clean room
Regulation; lattice; type; No. PB-1 PB-2
Dimensions (L × W × H mm) 785 × 600 × 690 785 × 600 × 690
Internal dimension (L × W × H mm) 600 × 600 × 600 600 × 600 × 600
Door interlock mode; electronic interlocking; mechanical interlock
Cabinet Material quality cold-rolled steel sheet, the surface electrostatic spray, matt white (can be customized various colors)
The inner wall of the material; stainless steel plate
Clean room transfer window manufacturers
Eight: air shower clean room transfer window parameters
Name: Lin Feng-mechanical interlocking transfer window; wind leaching electronic interlocking transfer window
Specifications: PB-3 PB-6
Dimensions (L × W × H mm) 980 × 700 × 1800 980 × 700 × 1800
Internal dimension (L × W × H mm) 660 × 700 × 600 660 × 700 × 600
Wind speed 25m / s over 25m / s or more
The number of nozzles 4 4
Wind leaching cycle 15s 15s
Door interlock way; mechanical interlocking; electronic interlocking
Cabinet material; quality cold-rolled steel sheet, the surface electrostatic spray, matt white (can be customized various colors)
Stainless steel plate inner walls
Power 380V 50HZ; three-phase 380V 50HZ; three-phase
Power 0.75KW 0.75KW
Nine: clean room transfer window installation method
Select a convenient location in the wall, then opening, hole transfer window generally higher than the large diameter of about 10MM, the transfer window into the wall, usually installed in the middle of the wall, to maintain a balance fixed, with rounded corners, or other decorative pieces to decorate transfer window and wall of the gap, a plastic seal can be modified. Clean room transfer window installation height determined in accordance with the needs of cleanroom project site, generally to facilitate the personnel to operate as a reference.
Shandong Ed purification clean room engineering professional solutions, the hospital operating room laminar flow engineering, clean room and other clean engineering, need to learn more about Ed clean room transfer window factory wholesale price, please contact Mr. Wang: 17863362888 0633-6862777